A dedicated outdoor air system doas should be investigated for 100% outdoor air applications. Hotgas bypass allows the unit to run better at off peak conditions. For comfort cooling, however, the addition of hot gas bypass is seldom necessary. Application engineering b u l l e t i n ae211160 october 1965 reformatted october 2010 hot gas bypass control systems on many refrigeration and air conditioning systems, the refrigeration load will vary over a wide range. Refer to the operation and maintenance manual for additional. This is the dehumidification option for trane precedent and vii products. Hot gas refrigerant reheat systems for packaged systems helps lower energy costs and increase comfort levelshelps to maintain specific temperature and humidity levels inside the building. Energy code limits the use of electric reheat to 42,000 btu and below. The design of reheat equipment hot gas reheat can help maintain specific humidity levels and.
Hotgas reheat, hotgas bypass, low ambient, modulating. Hot gas reheat hot gas reheat includes a condenser coil located in the supply airstream and a modulating refrigerant valve to control the supply air temperature and relative humidity. The gas then travels up the mixed gas lift tube, losing energy as it returns to the systems compressor suction inlet. We have 1 aaon cf series manual available for free pdf download. Opening this valve first further reduces the likelihood of damaging pressure shocks. In these systems, reheating is initiated when the supply air temperature falls below a preset dry bulb temperature. Hot gas bypass is recommended when the load on an evaporator. The idea is to siphon some of the waste heat off of the system but not enough to allow condensing to occur. The units compact footprint allows for easy installation where space is a concern. One drawback to hot gas defrost is the expansion and contraction of refrigerant lines due to temperature swings can be extreme if the lines run far enough. By turning the adjustment stem one complete turn clockwise, the pressure setting will increase approximately 4 psig. Suppose you have a conventional rooftop packaged unit with dx cooling and hot gas reheat. Hot gas reheat systems have to expend more energy for cooling. To control precisely both temperature and humidity one must be able to vary both the cooling coil temperature and the reheat coil temperature.
Trane offers hot gas reheat feature for rooftop units. No part of this work covered by the s herein may be reproduced or. Some boilers are provided with sh and rh bypass gas dampers for controlling reheat steam temperature. In addition, the hotgas bypass method was used to increase the pressure and temperature inside the outdoor coil to retard the frost formation and growth under the certain outdoor operating conditions. Decoupling msp improves the overall efficiency of a doas working with a decoupled building heating and cooling system. Energy is wasted whenever reheating is introduced to a zone that requires cooling. Pressureenthalpy diagram for parallel hot gas reheat cycle fig. Energy code limits the use of electric re heat to 42,000 btu and below. Aquazone constant volume watercooled horizontal water. Modulating hot gas reheat and hot gas filter sizes bypass systems on dx units table 9. For any corrective action issued by the controller, the dampers operate in the opposite direction. There are 2 check valves to prevent refrigerant flow into the reheat coil during. An overview of hot gas bypass its not enough to deliver an hvac system that meets the unique needs of each application.
Trane has developed hot gas reheat option for the voyager ii and precedent units. Hot gas bypass provides an artificial load on the evaporator by introducing a portion of high pressure, high temperature gas to the evaporator suction side of the system. Are uncontrollable humidity problems costing you a bundle. At the conclusion of this phase, the soft gas valve is closed.
The hot gas solenoid is opened and hot gas now flows more quickly through the drain pan, warming it, and then into the coil. Well, as we have learned in the past, refrigerant pressures are directly related to. Control of the trane hot gas reheat dx rooftop unit is accomplished through a dedicated. If the space is cooling, it is dehumidifying, whether humidistat is calling or not. Hot gas bypass provides an artificial load on the evaporator by introducing a portion of high pressure, high temperature gas to the evaporatorsuction side of the system. Good source for air reheat or dehumidification increases refrigerant charge hot water water heat reclaim diverting valve. Comparison between hotgas bypass defrosting and reverse. The hot gas enters the desuperheating chamber at an angle creating a circular hot gas path, wiping the walls of the chamber and giving up excess system heat. This may be due to differences in lighting, occupancy, product loading, ambient weather variations, or other factors. Modulating hot gas reheat aaon has addressed all of the above problems with a unique design incorporating a reheat coil, a modulating reheat hot gas valve, a modulating condenser hot gas valve, and an electronic controller. If return air conditions will be 72f 50% rh or lower the unit should incorporate the hot gas bypass option. The 50pch unit provides a practical and economical approach for comfort conditioning requirements in.
Hot gas reheat controls the supply air temperature and relative humidity without the need for auxiliary post heat i. A hot gas reheat system in essence wrings moisture from the air, providing occupants a more comfortable environment to learn, work, rehabilitate or play. The hot gas bypass valve explained by gary mccreadie. The owner also deserves a system that is the most reliable and the least costly to operate. Because temperature and pressure are directly related and too much heat transfer would occur on a nonpeak condition, a bypass valve would literally bypass the refrigerant from the supply of the evaporator back to the return of the compressor, bypassing the coil. The most popular approach to the hot gas reheat cycle. In specific cases, adding hot gas bypass to the refrigeration system may be necessary in order to achieve all three goals. Taken from my presentation called why dx systems fail. However, the frost is not retarded by the hotgas bypass method, and need to be removed by the reversecycle defrosting or hotgas bypass. This tactic keeps the compressor more fully loaded while the evaporator satisfies the partload condition. Hot gas bypass can stabilize the system balance point by diverting hot, highpressure refrigerant vapor from the discharge line directly to the lowpressure side of the system.
It is more efficient because it eliminates the need for a separate heat source to dehumidify the air, reducing heating costs. Hot gas reheat includes a condenser coil located in. Every hot gas reheat installation ive even done has been on packaged equipment where i route my hot gasliquid leaving the hgrh coil back to the discharge line. Some, or all, of the hot gas is taken and routed into the reheat coil. In the systems i typically deal with such as trane voyager this gas is then routed into the liquid line before the filter dryer. The hot gas then passes though the water to refrigerant coil. The onerow reheat coil has a face area equal to that of the evaporator coil. If return air conditions will be 72f 50 percent rh or lower, the unit should incorporate the hot gas bypass option.
However, this being a split im considering routing it back into the evaporator. Hot gas reheat in tranes systems recycles exhaust heat energy from the compressor and is intended to reduce indoor humidity while maintaining a comfortable air temperature. For the building owner, it means decreased maintenance expense due to damage caused by interior moisture. The hot gas bypass valve opens whenever the selector switch is moved to another position, bypassing refrigerant gas under pressure in. The use of hot gas bypass can be accomplished in several ways. The 50psh indoor watercooled heat pump unit is designed for horizontal installation with a variety of airflow configurations.
The coil is piped ahead of the expansion valve and can help add up to. How txv works thermostatic expansion valve working principle, hvac basics vrv heat pump duration. The sport version is typically applied on a refrigeration circuit utilizing hot gas for defrosting purposes, while the sportb offers the same capability in addition to a wide. The dehumidification option is a hot gas reheat coil located down stream of the evaporator coil. Even a unit equipped with hot gas bypass will cycle its compressor because the system will not bypass enough hot gas to operate continuously at low part load conditions. Hot gas reheat when indoor air quality is a concern, a hot gas reheat coil can be ordered to help control humidity levels. The hot gas bypass solenoid valve is a normally open, pilot operated valve which remains closed while the selector switch is on cool. Hot gas reheat provides dehumidification at part load and a safety factor for humid climates for more information. Figure 31 heat pump split system piping, suction down. The main purpose for adding hot gas bypass hgbp to any system is to prevent condensate from freezing on the surface of the evaporator coil when the system is operating at extremely low load conditions the hgbp valve is controlled by suction pressure, and its set point should be adjusted as low as possible to limit the amount of gas being bypassed and to minimize the negative. Helps reduce the possibility of material degradationdelivers air at temperature and humidity levels within the recommended ashrae ranges. The sdr series electric hot gas bypass valves ehgb modulate by the electronically controlled rotation of a step motor driving a gear train to position a pin or piston in a port, refer to figure 4. Its not enough to deliver an hvac system that meets the unique needs of each. Hot gas bypassreheat n none g hot gas bypass 015070 r hot gas reheat 015070 b hot gas bypass whot gas reheat 015070 rev 06 february 20d.
The hot gas bypass valve explained hvac know it all. This article covers standard external hot gas bypass. Hot gas bypass allows the unit to operate under a wide. This tech tip covers the standard external hot gas bypass. Additionally, hot gas bypass is used when the evaporator coil is designed for comfort cooling latent and sensible loads versus precision cooling all sensible loading. The result is that the units sensible cooling capacity adjusts to meet the required load. At this point the rest of the cooling cycle is completed. Aquazone 50psh watercooled horizontal water source heat. After hot gas leaves the coil, its a mixture of gas and liquid. Thoughts on combating the moisture with hot gas reheat. The hot gas bypass valve monitors the outlet pressure of the evaporator and will begin to modulate open as the load on the unit decreases to the point where the evaporator temperature is at the setpoint of the bypass valve.
Most air conditioning equipment spends 95% or more time oper ating at. Hot gas reheat coils are typically associated with commercial split systems. The motor is a two phase, bipolar, 12 volt dc, permanent magnet rotor style with a step angle of 3. With the hot gas bypass option now no longer needed, additional energy savings can. Hot gas bypass adjustment if the hot gas bypass opens below 58 psig, the valve must be adjusted to bring the activation point to 58 psig. Reheat temperature an overview sciencedirect topics.